Operator Reference
read_data_code_2d_model (Operator)
read_data_code_2d_model
— Read a 2D data code model from a file and create a new model.
Signature
read_data_code_2d_model( : : FileName : DataCodeHandle)
Description
The operator read_data_code_2d_model
reads the 2D data code
model file FileName
and creates a new model that is an
identical copy of the saved model.
The parameter DataCodeHandle
returns the handle of the new
model.
The model file FileName
must be created by the operator
write_data_code_2d_model
.
The default HALCON file extension for the 2D data code model is 'dcm'.
For an explanation of the concept of the 2D data code reader see the introduction of chapter Identification / Data Code.
Execution Information
- Multithreading type: reentrant (runs in parallel with non-exclusive operators).
- Multithreading scope: global (may be called from any thread).
- Processed without parallelization.
This operator returns a handle. Note that the state of an instance of this handle type may be changed by specific operators even though the handle is used as an input parameter by those operators.
Parameters
FileName
(input_control) filename.read →
(string)
Name of the 2D data code model file.
Default: 'data_code_model.dcm'
File extension:
.dcm
DataCodeHandle
(output_control) datacode_2d →
(handle)
Handle of the created 2D data code model.
Example (HDevelop)
* This example demonstrates how a model that was saved in an earlier * session can be used again by reading the model file * Create a model by reading by reading a data code model file read_data_code_2d_model ('ecc200_trained_model.dcm', DataCodeHandle) * Read a symbol image read_image (Image, 'datacode/ecc200/ecc200_cpu_010') * Read the symbol in the image find_data_code_2d (Image, SymbolXLDs, DataCodeHandle, [], [], \ ResultHandles, DecodedDataStrings) * Clear the model clear_data_code_2d_model (DataCodeHandle)
Result
The operator read_data_code_2d_model
returns the value 2 (
H_MSG_TRUE)
if the named 2D data code file was found and correctly read.
Otherwise, an exception is raised.
Possible Successors
Alternatives
See also
write_data_code_2d_model
,
clear_data_code_2d_model
Module
Data Code