Workflow for I/O devicesπŸ”—

Controlling I/O devicesπŸ”—

Depending on the used I/O device interface, certain actions may be performed on the interface before a connection to an actual device is being established. As an example, the OPC UA interface uses this mechanism to handle certificates for encrypted data acquisition sessions. These I/O interface actions are performed using the operator control_io_interface. See the documentation of your I/O device interface for detailed information.

Opening a connectionπŸ”—

You can query the available devices and other information of your I/O device interface using the operator query_io_interface. When connecting to your date acquisition device with open_io_device, the main parameters are the name of the corresponding HALCON I/O device interface and the name of the device itself. As a result, you obtain a so-called handle, with which you can access the device later, e.g., to open a transmission channel. Using the obtained handle of the transmission channel, you can acquire date with read_io_channel or write_io_channel.

With the generic parameters of open_io_device you can describe the configuration of your I/O device, which is necessary when using more complex configurations.

Detailed information about the parameters of open_io_device can be found in the documentation of your I/O device interface. More information is available for download from MVTec’s web server under MVTecInterfacesWWW.

Setting I/O device parametersπŸ”—

As described above, you can already set parameters when connecting to the I/O device with open_io_device. These parameters are the so-called generic parameters, because they are specific to the corresponding I/O interfaces. However, data acquisition devices differ widely regarding the provided functionality, leading to many more special parameters. These parameters can be customized with the operator set_io_device_param.

With the operator get_io_device_param you can query the current values of the parameters.

Reading and writing dataπŸ”—

Having opened a transmission channel, you read and write values using the operators read_io_channel and write_io_channel, respectively.

Closing the connectionπŸ”—

At the end of the application, you close the connection to the I/O transmission channel and the device to free its resources by first calling the operator close_io_channel, followed by the operator close_io_device.